Milwaukee Mw605 Max Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration

SKU: MOB-MT8105
Unit Price
Quantity
Subtotal
US$ 1,005.66
US$ 1,005.66
US$ 999.631%
2
US$ 996.101%
3
Congratulations! You got a great price!
Add to cart Added
Checkout
Options
Barcode
8106660036013
Description

The Milwaukee MW605 MAX Galvanic Portable Waterproof Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

The Milwaukee MW605 MAX DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatement plants and labs.

Design

Care and Maintenance

Probe Maintenance:
The silver cathode should always be bright and untarnished. If it is tarnished or stained, the cathode should be cleaned gently witha lint-free cloth.

  • Rinse the probe with deionized or distilled water.
  • Replace the membrane cap using fresh electrolyte.
  • Recalibrate meter.

Membrane Maintenance:

  • For accurate and stable measurements, perfect condition of the membrane surface is needed. Protect the thin membrane from scratches, abrasion or contact with solids.
  • If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
  • If fouled, rinse it carefully with distilled or deionized water. If damaged, replace the membrane cap.

Note: Change the membrane every 8 weeks or more frequently if used in a specially fouling environment. Check and replace the electrolyte fill solution every 4 weeks.

Storage:

After taking measurements, switch the meter off and clean the probe before storage. When not in use the probe should be stored with the plastic cap on.

For short term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.

For long term storage, the probe should be stored dry:

  1. Disconnet the probe from the meter.

  2. Unscrew the membrane cap.

  3. Remove any electrolyte solution from the cap.

  4. Rinse the probe anode/cathode assembly with distilleed water and blot dry.

  5. Screw the membrane cap onto the probe until the membrane cap is hand tight.

Shipping specs
Weight
0.6 lbs
Shipping from
This product is shipped from our supplier's warehouse in Pittsburg, CA, United States
Our guarantee
This product is brand new and includes the manufacturer's warranty, so you can buy with confidence.
Return policy
A 25% handling charge is levied against all authorized returns except those due to our error. Unauthorized returns are subject to a 40% handling charge. Damages & defects must be reported to us within 14 days.
Product questions
Please don`t mention your email and your phone in this field.
Customers Who Bought This Item Also Bought
You May Also Like
You recently viewed items